{"id":12243,"date":"2020-01-17T00:12:02","date_gmt":"2020-01-17T00:12:02","guid":{"rendered":"https:\/\/s3da-design.com\/?post_type=portfolio&#038;p=12243"},"modified":"2025-04-15T15:05:21","modified_gmt":"2025-04-15T15:05:21","slug":"hvac-design-for-neptune-south-development","status":"publish","type":"portfolio","link":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/","title":{"rendered":"HVAC Design for Neptune South Development, Brooklyn, NY"},"content":{"rendered":"<p style=\"margin-bottom: 5px;\"><i class=\"fa fa-user id-color\">&nbsp;<\/i> Client: Private <\/p>\n<p style=\"margin-bottom: 5px;\"><i class=\"fa fa-clock id-color\">&nbsp;<\/i> Date: November 2019<\/p>\n<p style=\"margin-bottom: 5px;\"><i class=\"fa fa-map-pin id-color\">&nbsp;<\/i> Location: Neptune South Development &#8211; Brooklyn, NY<\/p>\n<p><\/p>\n<p>The building is an existing office building that is being converted to residential and hotel occupancies. The HVAC system of the building consists of a 1,500-ton electric centrifugal chiller plant supplying chilled water to ceiling hung fan coils and floor mounted air handling units. The chiller plant rejects its heat to a 2-cell cooling tower which was sized with added redundancy. <\/p>\n<p>The location of the cooling tower was carefully coordinated with the surrounding structure around in order to allow the proper area for the CFM to enter the cooling tower intakes. Adequate clearance between the cooling tower intakes and the surrounding structure was determined using the applicable ASHRAE guidelines and input from the cooling tower manufacturer. The chiller plant is piped in a parallel configuration to allow for the simultaneous sequencing of the chillers.<\/p>\n","protected":false},"featured_media":12245,"template":"","categories":[771],"portfolio-categories":[862],"class_list":["post-12243","portfolio","type-portfolio","status-publish","has-post-thumbnail","hentry","categories-commercial","portfolio-categories-commercial"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v23.3 (Yoast SEO v26.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>HVAC Design for Neptune South Development, Brooklyn, NY - S3DA DESIGN Structural and MEP Design<\/title>\n<meta name=\"description\" content=\"The building is an existing office building that is being converted to residential and hotel occupancies. The HVAC system of the building consists of a 1,500-ton electric centrifugal chiller plant supplying chilled water to ceiling hung fan coils and floor mounted air handling units.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HVAC Design for Neptune South Development, Brooklyn, NY\" \/>\n<meta property=\"og:description\" content=\"The building is an existing office building that is being converted to residential and hotel occupancies. The HVAC system of the building consists of a 1,500-ton electric centrifugal chiller plant supplying chilled water to ceiling hung fan coils and floor mounted air handling units.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/\" \/>\n<meta property=\"og:site_name\" content=\"S3DA DESIGN Structural and MEP Design\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/S3DADesign\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-15T15:05:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@s3da_design\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/\",\"url\":\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/\",\"name\":\"HVAC Design for Neptune South Development, Brooklyn, NY - S3DA DESIGN Structural and MEP Design\",\"isPartOf\":{\"@id\":\"https:\/\/s3da-design.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg\",\"datePublished\":\"2020-01-17T00:12:02+00:00\",\"dateModified\":\"2025-04-15T15:05:21+00:00\",\"description\":\"The building is an existing office building that is being converted to residential and hotel occupancies. The HVAC system of the building consists of a 1,500-ton electric centrifugal chiller plant supplying chilled water to ceiling hung fan coils and floor mounted air handling units.\",\"breadcrumb\":{\"@id\":\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#primaryimage\",\"url\":\"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg\",\"contentUrl\":\"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg\",\"width\":800,\"height\":450,\"caption\":\"Neptune South Development Brooklyn NY\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/s3da-design.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HVAC Design for Neptune South Development, Brooklyn, NY\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/s3da-design.com\/#website\",\"url\":\"https:\/\/s3da-design.com\/\",\"name\":\"S3DA DESIGN Structural and MEP Design\",\"description\":\"S3DA Design is a San Diego-based structural and MEP design firm\",\"publisher\":{\"@id\":\"https:\/\/s3da-design.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/s3da-design.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/s3da-design.com\/#organization\",\"name\":\"S3DA Design Structural & Architectural Design\",\"url\":\"https:\/\/s3da-design.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/s3da-design.com\/#\/schema\/logo\/image\/\",\"url\":\"\",\"contentUrl\":\"\",\"caption\":\"S3DA Design Structural & Architectural Design\"},\"image\":{\"@id\":\"https:\/\/s3da-design.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/S3DADesign\/\",\"https:\/\/x.com\/s3da_design\",\"https:\/\/www.instagram.com\/s3dadesignfirm\/\",\"https:\/\/www.linkedin.com\/company\/s3da-design\/\",\"https:\/\/www.pinterest.com\/s3dadesign\/\",\"https:\/\/www.youtube.com\/channel\/UCPbyc8hxOOe2FHVbD9i7VxQ?view_as=subscriber\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"HVAC Design for Neptune South Development, Brooklyn, NY - S3DA DESIGN Structural and MEP Design","description":"The building is an existing office building that is being converted to residential and hotel occupancies. The HVAC system of the building consists of a 1,500-ton electric centrifugal chiller plant supplying chilled water to ceiling hung fan coils and floor mounted air handling units.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/","og_locale":"en_US","og_type":"article","og_title":"HVAC Design for Neptune South Development, Brooklyn, NY","og_description":"The building is an existing office building that is being converted to residential and hotel occupancies. The HVAC system of the building consists of a 1,500-ton electric centrifugal chiller plant supplying chilled water to ceiling hung fan coils and floor mounted air handling units.","og_url":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/","og_site_name":"S3DA DESIGN Structural and MEP Design","article_publisher":"https:\/\/www.facebook.com\/S3DADesign\/","article_modified_time":"2025-04-15T15:05:21+00:00","og_image":[{"width":800,"height":450,"url":"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@s3da_design","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/","url":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/","name":"HVAC Design for Neptune South Development, Brooklyn, NY - S3DA DESIGN Structural and MEP Design","isPartOf":{"@id":"https:\/\/s3da-design.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#primaryimage"},"image":{"@id":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#primaryimage"},"thumbnailUrl":"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg","datePublished":"2020-01-17T00:12:02+00:00","dateModified":"2025-04-15T15:05:21+00:00","description":"The building is an existing office building that is being converted to residential and hotel occupancies. The HVAC system of the building consists of a 1,500-ton electric centrifugal chiller plant supplying chilled water to ceiling hung fan coils and floor mounted air handling units.","breadcrumb":{"@id":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#primaryimage","url":"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg","contentUrl":"https:\/\/s3da-design.com\/wp-content\/uploads\/2020\/01\/Neptune-South-Development-Brooklyn-NY.jpg","width":800,"height":450,"caption":"Neptune South Development Brooklyn NY"},{"@type":"BreadcrumbList","@id":"https:\/\/s3da-design.com\/portfolio\/hvac-design-for-neptune-south-development\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/s3da-design.com\/"},{"@type":"ListItem","position":2,"name":"HVAC Design for Neptune South Development, Brooklyn, NY"}]},{"@type":"WebSite","@id":"https:\/\/s3da-design.com\/#website","url":"https:\/\/s3da-design.com\/","name":"S3DA DESIGN Structural and MEP Design","description":"S3DA Design is a San Diego-based structural and MEP design firm","publisher":{"@id":"https:\/\/s3da-design.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/s3da-design.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/s3da-design.com\/#organization","name":"S3DA Design Structural & Architectural Design","url":"https:\/\/s3da-design.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/s3da-design.com\/#\/schema\/logo\/image\/","url":"","contentUrl":"","caption":"S3DA Design Structural & Architectural Design"},"image":{"@id":"https:\/\/s3da-design.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/S3DADesign\/","https:\/\/x.com\/s3da_design","https:\/\/www.instagram.com\/s3dadesignfirm\/","https:\/\/www.linkedin.com\/company\/s3da-design\/","https:\/\/www.pinterest.com\/s3dadesign\/","https:\/\/www.youtube.com\/channel\/UCPbyc8hxOOe2FHVbD9i7VxQ?view_as=subscriber"]}]}},"_links":{"self":[{"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/portfolio\/12243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/types\/portfolio"}],"version-history":[{"count":1,"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/portfolio\/12243\/revisions"}],"predecessor-version":[{"id":39665,"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/portfolio\/12243\/revisions\/39665"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/media\/12245"}],"wp:attachment":[{"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/media?parent=12243"}],"wp:term":[{"taxonomy":"categories","embeddable":true,"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/categories?post=12243"},{"taxonomy":"portfolio-categories","embeddable":true,"href":"https:\/\/s3da-design.com\/wp-json\/wp\/v2\/portfolio-categories?post=12243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}